Boiler House Equipment

Total Dissolved Solids (TDS) Electrodes - SPECTORconnect | Gestra

Total Dissolved Solids (TDS) Electrodes - SPECTORconnect | Gestra
GESTRA SPECTORconnect – Conductivity Electrodes for TDS Control LRG 16-60, LRG 16-61, and LRG 17-60 are designed for continuous conductivity measurement in boiler water and TDS (Total Dissolved Solids) control in steam boilers and hot water systems. When paired with the LRR 1-60 controller, they provide continuous blowdown control. Integration with URS 60...

Total Dissolved Solids (TDS) Controllers - SPECTORmodul | Gestra

Total Dissolved Solids (TDS) Controllers - SPECTORmodul | Gestra
GESTRA SPECTORmodul – TDS Conductivity Controllers The LRR 1-50 / LRR 1-51 controllers are designed for continuous monitoring of boiler water conductivity and automated blowdown valve actuation. Conductivity is used as an indirect measurement of Total Dissolved Solids (TDS); as TDS increases, the controller opens the blowdown valve until the setpoint is...

Total Dissolved Solids (TDS) Controllers - SPECTORmodul Touch | Gestra

Total Dissolved Solids (TDS) Controllers - SPECTORmodul Touch | Gestra
GESTRA SPECTORmodul Touch – TDS Controllers The LRR 1-52 / LRR 1-53 controllers, in combination with the URB 55 operator unit, are used for boiler water conductivity monitoring, continuous surface blowdown control, and MIN/MAX limit supervision. Conductivity is used as a practical indicator of TDS, as dissolved solids increase with steam generation and...

Sample Coolers - SC32 / SC132 | ADCA

Sample Coolers - SC32 / SC132 | ADCA
ADCA SC32 / SC132 – Sample Cooler The ADCA SC32 and SC132 sample coolers are designed for cooling boiler water or steam samples prior to chemical analysis. Cooling prevents flashing of hot, pressurized samples, which can compromise measurement accuracy and present a burn hazard to operators. Operation The hot sample passes through a stainless steel coil...

Sample Coolers - SC32F / SC132F | ADCA

Sample Coolers - SC32F / SC132F | ADCA
ADCA SC32F / SC132F – Sample Cooler with Funnel The ADCA SC32F and SC132F sample coolers are designed for cooling boiler water or steam samples prior to analysis of conductivity, pH, or chemical parameters. Cooling mitigates flashing of hot, pressurized samples, which can affect measurement accuracy and pose burn hazards. Construction and Connections The...

Sample Coolers - SC32B / SC132B | ADCA

Sample Coolers - SC32B / SC132B | ADCA
ADCA SC32B / SC132B – Sample Cooler with Bolted Cover The ADCA SC32B and SC132B sample coolers are designed for cooling boiler water or steam samples prior to laboratory or on-site analysis. Cooling minimizes flashing of hot pressurized samples and reduces the risk of measurement errors or operator burns during sampling. Construction The B version...

Sample Coolers - SC332 - SC532 | ADCA

Sample Coolers - SC332 - SC532 | ADCA
ADCA SC332 / SC432 / SC532 – Sample Coolers The ADCA SC332, SC432, and SC532 sample coolers are designed to reduce the temperature of boiler water or steam samples prior to analysis of conductivity, pH, phosphate, or other chemical parameters. Cooling minimizes flashing of hot pressurized samples, which can otherwise result in inaccurate chemical readings...

Flash Vessel - RV | ADCA

Flash Vessel - RV | ADCA
ADCA RV – Secondary Steam Flash Vessel The ADCA RV is a vertical flash vessel designed for the recovery of secondary (flash) steam from high-pressure condensate. When condensate is discharged to a lower pressure, a portion re-evaporates and is separated in the vessel. The generated flash steam can be utilized for low-pressure steam consumers or heat...

Flash Vessel - RVST | ADCA

Flash Vessel - RVST | ADCA
ADCA RVST – Flash Vessel with Integrated Steam Trap The ADCA RVST is a vertical flash vessel designed for secondary steam recovery in systems where high-pressure condensate is discharged to a lower pressure. A portion of the condensate re-evaporates, and the resulting flash steam can be utilized in low-pressure steam consumers or heat exchangers. The...

Deaerator - ADG | ADCA

Deaerator - ADG | ADCA
ADCA ADG – Atmospheric Semi-Deaerator for Boiler Feedwater The ADCA ADG is an atmospheric semi-deaerator designed for preheating boiler feedwater and reducing dissolved oxygen and CO₂ content. The assembly consists of a deaeration head, horizontal storage vessel, and vent line. Under correct operation, residual O₂ is typically below 1.6 mg/l. Final oxygen...

Deaerator - TDG | ADCA

Deaerator - TDG | ADCA
ADCA TDG – Thermal Deaerator for Boiler Feedwater The ADCA TDG is a disc-type thermal deaerator designed for boiler feedwater treatment. The unit heats returned condensate and softened make-up water to remove dissolved oxygen and CO₂ prior to boiler entry. Technical documentation specifies oxygen reduction capability to below 0.02 mg/l, with final...

Flash Condensing Heads - FCD | ADCA

Flash Condensing Heads - FCD | ADCA
ADCA FCD – Flash Steam Condensing Head ADCA FCD is a mixing and condensing head for secondary steam, designed for boiler feedwater tanks. It is applied where flash steam from vent lines or TDS recovery systems must be absorbed into make-up water, rather than vented to atmosphere. Operation The unit receives cold make-up water, condensate return,...

Blowdown Vessels - BEX | ADCA

Blowdown Vessels - BEX | ADCA
ADCA BEX – Blowdown Expansion and Cooling Unit The ADCA BEX is an expansion and cooling vessel designed for boiler blowdown water and hot industrial effluents prior to discharge into drains or sewer systems. Operating at atmospheric pressure, hot water enters the vessel and is mixed with cooling water via a controlled valve, ensuring the outlet...

Blowdown Vessels - BV | ADCA

Blowdown Vessels - BV | ADCA
ADCA BV – Blowdown Expansion Vessel The ADCA BV is designed for boiler house applications, specifically for cooling boiler blowdown water and hot effluents prior to discharge into drainage systems. The vessel acts as a flash expansion chamber: a portion of the incoming hot water is converted to flash steam, while the remainder is collected as hot...

Boiler Feed Tanks - BFT | ADCA

Boiler Feed Tanks - BFT | ADCA
ADCA BFT – Boiler Feedwater Storage Tank ADCA BFT is a horizontal feedwater storage tank for steam boiler systems. It collects softened make-up water and returned condensate, providing a buffer volume for feedwater pumps and ensuring stable suction conditions. The tank is designed for industrial steam applications where consistent feedwater supply and...

Level Indicators Magnetic - MLI | ADCA

Level Indicators Magnetic - MLI | ADCA
ADCA MLI – Magnetic Level Indicator The ADCA MLI is a bypass-type magnetic level indicator designed for continuous local level indication or level control in ADCA ECRU units, skid packages, condensate vessels, and industrial tanks. The process fluid is contained within a metallic chamber rather than a glass tube, reducing potential leakage points compared...

Cooling Device - HCC | ADCA

Cooling Device - HCC | ADCA
ADCA HCC – Hot Condensate Cooler Vessel The ADCA HCC is used in condensate lines where discharges from higher-pressure steam traps are routed to a lower-pressure, lower-temperature condensate header. The rapid pressure drop can generate flash steam; if this condenses suddenly within cooler condensate, it may cause noise, vibration, and water hammer....

Exhaust Heads - EH | ADCA

Exhaust Heads - EH | ADCA
ADCA EH – Exhaust Head for Open Vent Lines The ADCA EH exhaust head is installed at the end of vertical vent or blowdown lines from blowdown vessels, feedwater tanks, and auxiliary steam vessels. Its primary function is to separate moisture from the outgoing steam, reduce discharge velocity, and ensure safe drainage of retained condensate within the...

Condensate Lifting Pots - LIPO | ADCA

Condensate Lifting Pots - LIPO | ADCA
ADCA LIPO – Condensate Lift Vessel ADCA LIPO is installed in condensate lines where discharge from a steam trap must be elevated to a higher-level condensate header. Its use mitigates hydraulic shock and noise caused by rapid condensation of secondary steam in cooler condensate, improving process stability and protecting downstream equipment. Operating...

Sample Cooler - SACO | BLU ZAC

Sample Cooler - SACO | BLU ZAC
BLU ZAC SACO – Sample Cooler The BLU ZAC SACO is a compact heat exchanger designed for cooling or heating process sample fluids. In boiler houses, it is primarily used to cool boiler water, condensate, or hot water samples prior to conductivity, pH measurement, or chemical analysis. Operation is based on a helical coil immersed in a small vessel with a...

Sampling System - SASY | BLU ZAC

Sampling System - SASY | BLU ZAC
BLU ZAC SASY – Sampling Station BLU ZAC SASY is a prefabricated sampling station for liquids and gases, engineered per application. Typical use cases include boiler rooms, condensate lines, feedwater, and process points where samples must be taken under controlled pressure, temperature, and flow. The system is available with or without an integrated...

Borosilicate glass acc. to DIN 7081 | Noris

Borosilicate glass acc. to DIN 7081 | Noris
NORIS DIN 7081 – Borosilicate Glass for Level Gauges NORIS glasses according to DIN 7081 are replacement borosilicate glass plates for visual level gauges in boilers, pressure vessels, and industrial liquid circuits. These are not complete gauge assemblies; selection is based on compatibility with existing gauge bodies, dimensional fit, gasket selection,...

Gaskets for sight glasees | Noris

Gaskets for sight glasees | Noris
NORIS – Gaskets for Sight Glass Level Gauges NORIS gaskets are used in sight glass level gauges with glass plates, serving as sealing elements between the glass, gauge body, and cover. These are not level indication components but critical sealing spares that directly affect leakage, glass compression, and safe operation under steam or process liquid...
Showing 25-47 of 47 item(s)