Valpres 7608 PN16-F1 two-piece flanged ball valve
The Valpres 7608 is a split-body flanged ball valve used for flow isolation in industrial piping. It is available from DN15 to DN100 with DIN flanges and PN16 or PN40 pressure rating depending on size and version. Operating temperature range is -20°C to +160°C. Vacuum service is stated down to 10⁻³ torr.
Construction and material variants
- 760801: body and end connection in 1.4408 / ASTM A351 CF8M, with ball in A479 TP316 or CF8M. This version is typically selected where corrosion resistance to water, light chemicals, or process fluids is required.
- 760802: body in ASTM A352 LCB, with ball in A479 TP304 or CF8. This version is generally used on carbon-steel piping systems where stainless wetted trim is acceptable.
Variant selection should be based on fluid chemistry, chloride content, corrosion allowance, temperature, pressure class, piping material, and project specification.
Sealing arrangement
The valve uses PTFE seats, PTFE and Graphoil stem sealing, an FKM O-ring, and a PTFE thrust washer. This configuration is intended for isolation duty. It should not be used as a continuous throttling valve, since partially open ball valves can generate seat wear, noise, vibration, and unstable control.
Suitable media and services
- industrial water and utility water
- compressed air
- inert gases
- light chemical services compatible with PTFE, FKM, and the selected body material
- process utility lines and auxiliary production circuits
- HVAC distribution and plant services
For steam, thermal oil, aggressive chemicals, oxygen, vacuum, or cyclic high-temperature duty, compatibility of seats, elastomers, pressure rating, and leakage class should be verified before procurement.
Actuation and automation
The valve body includes an ISO mounting pad for pneumatic or electric actuators. Available mounting interfaces include F04, F05, F07, and F10 depending on DN. Actuator sizing should consider differential pressure, breakaway torque, operating frequency, safety position, air supply pressure, and any fail-open or fail-closed requirement.
Standards and certifications
- TÜV SIL 3 reference for safety-related applications
- Fire Safe according to EN ISO 10497 / API 607
- Fugitive emissions testing according to ISO 15848-1
Typical industrial use cases
- manual or automated isolation on process utility headers
- skid-mounted equipment inlet and outlet isolation
- HVAC plant rooms and industrial cooling loops
- maintenance block valves for pumps, filters, and heat exchangers
FAQ
Is the Valpres 7608 a control valve?
No. It is primarily an on/off isolation valve. Use a control valve or characterized ball valve for modulating service.
How should the PN rating be selected?
Select PN16 or PN40 according to design pressure, temperature, flange standard, piping class, and project valve specification.
Description
Certifications
TUV SIL 3
FIRE-SAFE Acc. EN ISO 10497/API 607
F.E. TESTED ISO15848-1