Emergency shower wall mounted, with eye/face wash unit with bowl & lid - ClassicLine - BR 868 085 | B-Safety
B-Safety BR 868 085 ClassicLine
Wall-mounted emergency safety shower and combined eye/face wash unit with bowl and hinged cover. Designed for installation in laboratories, chemical mixing areas, storage facilities, and container filling stations where both body and eye/face decontamination are required from a single wall-mounted assembly.
Technical Data
- Type: ClassicLine, wall-mounted configuration
- Materials: Stainless steel piping and flanges, plastic components
- Total height: 1625 mm
- Body shower arm projection: 630 mm
- Eye/face wash installation height: 810 mm ±100 mm
- Water inlet: ¾” female, top/bottom connection, suitable for circulation line integration
- Operating pressure: 1.5–3 bar
- Body shower flow: 50 l/min (optional 75 or 110 l/min variants)
- Bowl outlet: 1 ½” male
Construction and Operation
All wetted metallic parts (piping, flanges, arm) are stainless steel with green chemical-resistant powder coating. The ¾” body shower ball valve is dezincification-resistant brass, actuated by a 700 mm pull rod. The shower head is self-draining plastic with integrated 50 l/min flow regulator.
Eye/Face Wash Unit with Cover
Unit comprises ABS bowl, body, and hinged cover (UV and impact resistant). The cover serves as both contamination shield and activation lever; flow initiates upon lowering. Includes 3/8” valve, chrome-plated brass spray regulators, and 3/8” flow control valve for spray height and flow adjustment.
Standards and Certifications
Complies with EN 15154-1:2006, EN 15154-2:2006, EN 15154-5:2019, ANSI Z358.1-2014. Additional references: DIN 1988, EN 1717, DIN-DVGW/DVGW, GOST-R.
Maintenance
Routine inspection of flow rate, dynamic pressure, valve tightness, cover actuation, spray regulator cleanliness, bowl condition, and unobstructed 1 ½” drainage is required.
Applications and Media
- Suitable for potable water and decontamination media
- Recommended for chemical processing, laboratories, and hazardous material handling zones
- Variants available for increased flow rates and specific installation heights