Flow - Series TM | Tecfluid Tecfluid - 1
Flow - Series TM | Tecfluid Tecfluid - 2
Flow - Series TM | Tecfluid Tecfluid - 3
Flow - Series TM | Tecfluid Tecfluid - 1
Flow - Series TM | Tecfluid Tecfluid - 2
Flow - Series TM | Tecfluid Tecfluid - 3

Flow - Series TM | Tecfluid

Tecfluid TM Turbine Flowmeter

The Tecfluid TM is a turbine flowmeter designed for clean liquids with low to medium viscosity. The helical rotor rotates at a speed proportional to the flow rate. An external pickup coil generates a pulse signal, which is converted to flow rate, total volume, 4–20 mA, or pulse output via appropriate electronics.

Operating Range

  • Water flow: 30 l/h to 650 m³/h
  • Accuracy: ±0.5% of measured value
  • Repeatability: ±0.1%
  • Turndown ratio: 10:1
  • Viscosity: up to approx. 100 mPa·s
  • Fluid temperature: -50 to +170 °C
  • Pressure: PN40 up to DN50, PN16 from DN65 to DN150

Materials and Connections

Body: EN 1.4404 / AISI 316L. Rotor available in AISI 431 / AISI 329 / AISI 430. Shaft and bearings: tungsten carbide / graphite. Connections: flanges EN 1092-1 DN15–DN150, ASME B16.5 ½”–6”, BSP/NPT threads, and sanitary fittings ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP®.

Electronics and Outputs

Available modules: CIP II for totalization (battery powered), CP420 / CH420 for flow/volume indication and 4–20 mA, CH420 with HART, MT03F for batch control and alarms, DFD420 for pulse scaling/division. ATEX Exd version available. Basic pickup can be classified as simple apparatus per EN 60079-11 when used with suitable isolator or Zener barrier.

Installation and Maintenance

Piping must be full, free of air or vacuum. Require 10 × DN upstream and 7 × DN downstream, or 5 × DN upstream with flow straightener. Install filter before meter; manual specifies max opening 200 μm to protect rotor. Control valves downstream, pumps upstream to minimize cavitation.

Applications

Chemical and petrochemical lines, tank filling, batch dosing, fuel consumption monitoring in burners, condensate measurement in boiler rooms. Not suitable for gases or steam in vapor phase.

Description

Description

Medidores de caudal de área variable y tubo metálico para líquidos, gases y vapor.

Las turbinas TM44 son medidores de caudal de líquidos o contadores volumétricos dependiendo de los sistemas electrónicos empleados. Adecuada para todos los sentidos de flujo con funcionamiento en vertical u horizontal. Liquidos limpios y de baja viscosidad.

Technical specifications

mV output by means of pick-up coil proportional to the flow.

Compatible with associated electronic converters CIP / CP / MT03 / DFD420 series. Others on request.

Considered as “Simple Aparatus” according to ATEX.

Measuring range

  • 300 l/h … 1100 m3/h H2O

Accuracy

  • ± 0,5%

Connections

  • DIN2502 DN15…DN50 PN40 flanges
  • DN10…DN500 PN16
  • ANSI flanges
  • BSP o NPT threaded connections
  • DIN11851 sanitary connection

Materials

  • Body: EN 1.4404 (AISI 316L)
  • Propeller: EN 1.4416 (AISI 430)

Options

  • Design for high pressure on request
  • Special design for converters from different manufacturers

Declarations of Conformity

Certifications