Solenoid Diaphragm Valve 2/2-Way - Series 240/240FL | AWS AWS - 1
Solenoid Diaphragm Valve 2/2-Way - Series 240/240FL | AWS AWS - 2
Solenoid Diaphragm Valve 2/2-Way - Series 240/240FL | AWS AWS - 1
Solenoid Diaphragm Valve 2/2-Way - Series 240/240FL | AWS AWS - 2

Solenoid Diaphragm Valve 2/2-Way - Series 240/240FL | AWS

Electromagnetic Diaphragm Valve 2/2 AWS Type 240 / 240FL

The AWS Type 240 is a 2/2-way electromagnetic diaphragm valve, pilot-operated. It is used for on/off isolation of lines with available differential pressure. A minimum Δp of 0.5 bar between inlet and outlet is required for proper operation, thus it is not recommended for gravity discharge or zero backpressure circuits.

Technical Data

  • DN 13 to DN 50 for threaded connection
  • DN 25 to DN 100 for flanged version 240FL
  • Operating pressure: 0.5–16 bar, depending on DN and NC/NO operation
  • Connections: G 3/8” to G 2”, NPT or flange
  • Body: brass or stainless steel 1.4408
  • In flanged version: stainless steel body only
  • Seals: NBR, EPDM, FKM
  • Medium temperature: -10 to +130 °C, depending on elastomer
  • Ambient temperature: up to +50 °C
  • Viscosity: ≤20 cSt
  • Electrical connection: DIN EN 175301-803 Form A
  • Protection: IP65 with plug mounted

Flow Areas

DN Connection Kv
13 G 3/8” or G 1/2” 3.8 m³/h
20 G 3/4” 6.5 m³/h
25 G 1” / flange 10.3 m³/h
32 G 1 1/4” / flange 18.9 m³/h
40 G 1 1/2” / flange 25.8 m³/h
50 G 2” / flange 41.2 m³/h
65–100 flange 61.0–109.2 m³/h

NC / NO and 240 / 240FL

The series is available in NC and NO. In NO versions, allowable pressures are lower for certain sizes. The 240FL is selected when a flanged connection, larger diameter, or stainless steel body 1.4408 is required in the line.

Applications

Suitable for clean water, neutral fluids, compressed air, and compatible gases without solids. Typical uses: process water networks, auxiliary lines, pressurized tank filling, industrial skids, HVAC water, and high Kv air lines.

Options

Available coils: 230 V AC, 24 V DC, and special voltages, LED plug, manual override, bracket, oil/grease-free cleaning, silicone/LABS-free version, fully encapsulated coil IP67, and Ex coil II 2G Ex mb IIC T4 Gb / II 2D Ex mb tb IIIC T130°C Db.