Tecfluid LP – Level Indicator, Switch, and Transmitter with Displacer

The Tecfluid LP series is designed for liquid level measurement in process tanks, providing local indication with optional limit switches or analog output. Unlike float-type surface switches, the LP operates with a displacer element suspended on a spring, based on Archimedes’ principle. Changes in liquid level alter the apparent weight of the displacer, and movement is transmitted to the indicator via magnetic coupling.

Operating Range

  • Measuring span: 300 mm to 6 m
  • Accuracy: ±5 mm
  • Liquid density: 0.6–2 kg/l
  • Operating pressure: PN40 standard; other ratings available on request
  • Process temperature: -60 to +150 °C standard, up to -120 to +400 °C with thermal spacer
  • Installation: vertical from tank top or side-mounted with external chamber 80ME

Connections and Materials

Standard models: LP80 (flanged) and LP81 (threaded). Connections available: EN 1092-1 DN40 PN40, BSP, 1½” NPT, ASME B16.5, or JIS on request. Wetted parts: EN 1.4404 / AISI 316L, Hastelloy C, Titanium; displacer also available in PVC, PP, or PVDF for chemical compatibility.

Outputs and Automation

  • AMM: 1 or 2 adjustable microswitches, 3(1) A / 250 V (EN 61058)
  • AMD: 1 or 2 NAMUR inductive sensors (EN 60947-5-6)
  • TH7 / TH7H: 2-wire transmitter, 4–20 mA, HART protocol (TH7H)
  • MT03L: electronic converter, optional Modbus RTU RS485

Standards and Certifications

Complies with PED 2014/68/EU, EMC 2014/30/EU, WEEE. ATEX 2014/34/EU and IECEx available for suitable versions. Ex models are intrinsically safe Ex ia; circuit parameters must be observed.

FAQ

When to select LP over LE?
For high pressure/temperature, contaminated media, or interface measurement requirements.

Is the measurement continuous?
Yes, with local indication and optional 4–20 mA output. AMM/AMD modules provide limit alarms or interlock points.

Description

Description

Indicador/Transmisor de nivel de líquidos. Indicación de nivel en caja indicadora. Equipo apto para condiciones extremas de trabajo (presión, temperatura, resistencia química).

Technical specifications

Local indication.

Length

  • 0,3 … 6 m

Accuracy

  • ±5mm of the measured value

Connections

  • DIN DN40 flanges
  • Thread fittings G 1 1/2”/ 1 ½”NPT
  • Others on request
  • Top or side mounted

Materials

  • EN 1.4404 (AISI 316L). Floats in PP, PVC, PVDF

Options

  • 1 or 2  limit switches
  • 4-20 mA analog output, Ex version on demand
  • HART ™ protocol on demand
  • Indicator box optional in AISI 316L or PP
  • Explosion proof enclosure on demand, pending of ATEX certification

Declarations of Conformity