Flow - Series VH | Tecfluid Tecfluid - 1
Flow - Series VH | Tecfluid Tecfluid - 2
Flow - Series VH | Tecfluid Tecfluid - 1
Flow - Series VH | Tecfluid Tecfluid - 2

Flow - Series VH | Tecfluid

Pallete Flow Switch Tecfluid VH

The Tecfluid VH is a mechanical flow switch for liquids in pipelines DN32…DN500. Flow displaces a paddle inside the pipe; this movement is transferred to a permanent magnet, which actuates an SPDT reed switch without direct contact between the switch and the process fluid. The switching point corresponds to a paddle angle of approximately 30°–45° from the zero-flow position.

Operating Ranges and Conditions

  • Indicative switching flow: 2…120 m³/h, depending on DN
  • Instrument connection: G1, optionally 1” NPT
  • Fluid/ambient temperature: -40…+125 °C
  • Pressure rating: PN25 for body EN 1.4404 / AISI 316L, PN10 for PTFE
  • Protection: IP65 with DIN 43650-A connector

Variants

  • VH35: Horizontal pipe, flow left–right or right–left
  • VH37 AISI 316L BD: Vertical pipe, upward flow, with spring return
  • VH39 PTFE BD: Vertical pipe, upward flow, with magnetic return

Electrical Contact

Output is one non-adjustable reed contact, potential-free. Limits: 5 W, 120 VAC / 175 VDC, 0.18 AAC / 0.25 ADC. For relay coils or solenoid valves, surge protection is required; for higher loads, use an interposing relay.

Installation

For VH35, the paddle must hang vertically and be perpendicular to the flow, without touching the pipe wall. The paddle axis center must align with the pipe’s internal diameter. VH37/VH39 are for upward vertical flow only.

Applications

Suitable for flow monitoring in heating/cooling circuits, hydraulic systems, water treatment, pools, fire protection, pulp and paper, chemical and petrochemical lines where a simple flow presence signal is required.

FAQ

Does it measure flow rate? No. It is a flow limit switch, not an analog flowmeter.
Can it be used for gases? Not for the VH series; intended for liquids.
Is it ATEX certified? May be considered simple apparatus per IEC 60079-11, but is not ATEX marked.

Description

Description

Detector de caudal por sistema lámina-paleta para líquidos. Fácil instalación y utilizable en tuberías horizontales y verticales con flujo ascendente. Total estanqueidad, sin contacto entre el fluido y los sistemas de detección reed.

Technical specifications

1 switch (not adjustable)

Measuring range

  • 15 l/h … 16000 l/h H2O

Accuracy

  • ±5% f.s.

Connections

  • 1” BSP

Materials

  • EN 1.4404 (AISI316L), PTFE
  • Others on request

Declarations of Conformity