Relative & Differential Pressure Transmitter - DP5-A | OMC OMC - 1
Relative & Differential Pressure Transmitter - DP5-A | OMC OMC - 1

Relative & Differential Pressure Transmitter - DP5-A | OMC

OMC DP5-A – Pneumatic Differential Pressure Transmitter

The DP5-A is a pneumatic differential pressure transmitter operating on a force-balance principle. The measuring unit detects ΔP via a diaphragm capsule, while the transmission unit converts displacement into a proportional pneumatic output signal. Signal generation utilizes a flapper-nozzle relay with bellows feedback.

Technical Specifications

  • Static pressure limit: 100 bar
  • Measuring ranges: 30–170 kPa, 5–52 kPa, or 2.5–7.5 kPa
  • Output: 20–100 kPa, 0.2–1 bar, or 3–15 psi
  • Air supply: 135 kPa ±10%
  • Accuracy: ±0.5% F.S.D.
  • Ambient temperature: -40 to 120 °C
  • Ingress protection: IP55 (IEC 529)
  • Process connections: 1/2" NPT-F, adapters for 1/4" NPT-F available

Materials and Media Compatibility

Body options: carbon steel A216 WCC or stainless steel A351 CF3M. Diaphragms: AISI 316L, Monel, or Hastelloy C, with silicone oil or PFPE Galden fill. Seals: PTFE or Viton. For oxygen service with Galden, operating temperature is -20 to 40 °C.

Typical Applications

  • Level measurement in closed vessels via hydrostatic pressure
  • Filter and heat exchanger monitoring
  • Pressure drop measurement in air, gas, or liquid lines
  • Pneumatic control loops without electronic signals
  • Installations requiring ATEX; 2014/34/EU version available for Gas Zone 1 / Dust Zone 21

Variant Selection

For low differential pressures, select 3" diaphragm or ultrafeedback version. For corrosive or sour service, consider Hastelloy C, Monel, or NACE MR0175-compliant materials. Zero elevation and zero suppression available for wet/dry leg level applications.

FAQ

Is electrical power required?
No. Only clean instrument air is needed.

When is it used instead of an electronic transmitter?
In existing pneumatic loops, hazardous areas, or where pneumatic signal maintenance is a functional requirement.

Datasheet and documents

Description

The DP5-A works on the force balance principle and consists of two main units: The measuring unit which detects the differential pressure variation and consists of two forged bodies and a measuring capsule. The transmission unit converts the differential force applied to the measuring element into a proportional output pneumatic signal. The output pressure, generated by a flapper nozzle relay, feeds the feedback bellows with a rising pressure until the balance between bellows force and measuring element is reached. The whole transmission unit is contained within a water-resistant housing.

STATIC PRESSURE LIMIT 100bar

Version according to Directive 2014/34/UE "ATEX" are available

tuvATEX documents Gas Zone 1 / Dust Zone 21 DIRECTIVE 2014/34/UE