Needle valve Clamp - GRADUATE HANDWHEEL - 658230 | 4G Ghidini 4G Ghidini - 1
Needle valve Clamp - GRADUATE HANDWHEEL - 658230 | 4G Ghidini 4G Ghidini - 1

Needle valve Clamp - GRADUATE HANDWHEEL - 658230 | 4G Ghidini

Needle Valve 4G Ghidini 658230 – Clamp with Calibrated Handwheel

Manual needle valve for gradual adjustment of small flow rates in clean liquids or gases. The 658230 version features Clamp connections according to DIN 32676 Tab. 4 Reihe C and Tab. 2 Reihe A, AISI 316L body, polished exterior surface, and calibrated handwheel. Available in 1/2”, 3/4”, DIN 34, and 1”.

Technical Specifications

  • Operating Temperature: -20°C to +160°C
  • PN 160: size 1/2”
  • PN 100: 3/4”, DIN 34, and 1”
  • Body, needle, screw, stopper nut, and graduate ring material: AISI 316L
  • Handwheel, washer, nut, and screws: AISI 304L
  • Sealing: O-rings FKM, seats PTFE and PTFE with glass reinforcement

Operational Use

The calibrated handwheel is used when the operator needs to return the valve to a specific open position after cleaning, Clamp disconnection, or setting change. The position indication is not a flow measurement; actual flow depends on ΔP, viscosity, temperature, and line characteristics.

Typical Applications

  • Sampling lines in clean media
  • Small flows in food, beverage, or pharmaceutical skids
  • Auxiliary CIP/SIP circuits within temperature and material limits
  • Dosing or trimming lines with sanitary connections
  • Applications requiring disassembly without threads in the process zone

Not suitable for slurries, suspended solids, or viscous products, as the needle creates a limited flow cross-section.

Difference from Simple Clamp Version

Compared to the 658030, the 658230 is selected when repeated manual adjustment and visual position reference are required. For simple isolation or occasional adjustment, the non-calibrated version may suffice.

Standards and Options

Upon request, an antistatic device ATEX II 2G Ex h IIC T4 Gb / II 2D Ex h IIIC T135°C Db and M.O.C.A. CE 1935/2004 compliance are available.

Standard (Options)
  • DIN
Connection (Options)
  • Clamp
Material (Options)
  • 1.4404
Pressure Rating (Options)
  • PN 100
  • PN 160

Datasheet and documents

Description

PIN valve

Drive: GRADUATE Handwheel

Connection: CLAMP normative DIN 32676 TAB.4 REIHE C e TAB.2 REIHE A

Material: Aisi 316L

Measure: from 1/2” to 1”

Operating temperature: -20°C+160°C

Outer finish: Polished

On request:

Antistatic device ATEX:

II 2G Ex h IIC T4 Gb

II 2D Ex h IIIC T135°C Db

M.O.C.A. CE 1935/2004