Water Control Gates - Hand Stop Gate | Wey Valves
Water Control Gates - Hand Stop Gate | Wey Valves

Water Control Gates - Hand Stop Gate | Wey Valves

WEY Hand Stop Gate – Type 5.0

The WEY Hand Stop Gate 5.0 is a removable gate for temporary isolation during inspection, cleaning or maintenance. It is installed at channel, chamber and basin openings and is inserted or removed manually using a dedicated handle. The gate provides bidirectional shut-off.

Technical Data

  • Clear width: 100–1200 mm

  • Water head: 0.15–1.20 m

  • Frame: stainless steel 1.4404

  • Gate plate: stainless steel 1.4404

  • Seal: PVC

  • Operation: removable handle

  • Installation: embedded in concrete or surface-mounted with anchors

  • Construction: project-specific according to opening dimensions and hydrostatic load.

The gate plate is reinforced according to the specified water pressure. The frame uses a rounded bottom profile and must be installed without distortion. Frame alignment, wall flatness and guide parallelism must be checked before final grouting or anchor tightening.

Operation and Installation

No permanently mounted actuator is provided. The gate is operated directly with a removable handle. Installation and embedding must be completed with the gate in the closed position, while sealing surfaces must remain free from concrete and debris.

Applications

Wastewater, stormwater, raw water, industrial water, mixed-water systems and seawater installations.

FAQ

Is the Hand Stop intended for level control?
No. It is used primarily for temporary full isolation during maintenance or inspection.

What maintenance is required?
Guides and sealing surfaces must remain clean. Elastomer seals require periodic lubrication, and at least four operating cycles should be performed annually.

Description

Hand stops are mainly used temporarily, for inspection procedures. That is why they can only be operated with a handle. Our hand stops are made to measure from high-quality stainless steel for each order, and are tighter than the standard prescribes. They are also bidirectional in both flow directions.

Characteristics

  • Design: Sluice gate
  • Width: 100 – 1200 mm
  • Head of water:0.15 – 1.20 m

Details

The robust metal yoke enables the optimal, simple assembly of mechanical or inductive limit switches. The yoke can be removed from one side. This makes it easier to access the mechanical parts.

Frame design has a round bottom profile for setting in concrete or doweling.

The robust metal yoke enables the optimal, simple assembly of mechanical or inductive limit switches. The yoke can be removed from one side. This makes it easier to access the mechanical parts.

Reinforced gate, adapted to the required water pressure.

Application Areas

Infrastructure

e.g. Waste water, Rainwater, Industrial water, Mixed water ...

Water treatment

e.g. Seawater ...

Waste water treatment plants

e.g. Waste water, Raw water ...

Material Of Construction

Part
Frame1.4404
Gate1.4404
SealPVC

Other materials upon request