Hafner ATEX Mechanical Air Valves

Hafner ATEX-certified mechanical valves are specified for pneumatic circuits in hazardous areas where actuation must be mechanical rather than solenoid-based. These valves are suitable for end-of-stroke detection, mechanical interlocks, and pneumatic sequencing in environments requiring ATEX documentation and compliance.

Available Versions

  • BV 311 301 Ex: Plunger valve, 3/2, single-acting, spring return, NC/NO configuration, G 1/8” ports, flow rate 280 l/min, pressure range -0.9…10 bar, actuation force 14 N.
  • BV 511 301 Ex: Plunger valve, 5/2, single-acting, spring return, G 1/8”, 280 l/min, -0.9…10 bar, actuation force 14 N.
  • BA 311 301 Ex: Panel-mounted, Ø22 mm hole, 3/2 NC/NO, G 1/8”, 280 l/min, -0.9…10 bar.
  • BA 511 301 Ex: Panel-mounted, 5/2, G 1/8”, 280 l/min, -0.9…10 bar.

Operation and Selection

3/2 valves are used for pneumatic signaling or single-acting cylinders. 5/2 valves are intended for double-acting cylinders, alternating supply and exhaust between actuator sides.

Selection criteria include:

  • 3/2 or 5/2 function,
  • NC or NO configuration,
  • mechanical plunger or panel push actuation,
  • required actuation force,
  • line pressure and flow demand,
  • installation location within ATEX zone.

Applications

Typical uses: cylinder end-position feedback, mechanical sequencing, pneumatic panels in hazardous zones, packaging systems, chemical plants, and installations where electrical actuation at the switching point is not permitted.

Maintenance

Routine checks: air quality, leakage at exhausts, spring return integrity, plunger wear, secure panel mounting, and absence of trapped pressure. In ATEX installations, replacement must use an equivalent certified valve.

Datasheet and documents

Description

Explosion proof stem valve | monostable | mechanical spring return | universally usable - NC/NO | ATEX

Type numberPort sizeAir flowOperating pressureActuating forceFunctionPort size / port position
BV 311 301 ExG 1/8"280 l/min-0,9...10 bar14 Nspring return | NC/NOports at the side

Explosion proof stem valve | monostable | mechanical spring return | ATEX

Type numberPort sizeAir flowOperating pressureActuating forceFunctionPort size / port position
BV 511 301 ExG 1/8"280 l/min-0,9...10 bar14 Nspring returnports at the side

Explosion proof valve for panel mounting | monostable | mechanical spring return | for Ø22 mm panel mounting hole | universally usable - NC/NO | ATEX

Type numberPort sizeAir flowOperating pressureActuating forceFunctionPort size / port position
BA 311 301 ExG 1/8"280 l/min-0,9...10 bar14 Nspring return | NC/NOports at the side

Explosion proof valve for panel mounting | monostable | mechanical spring return | for Ø22 mm panel mounting hole | ATEX

Type numberPort sizeAir flowOperating pressureActuating forceFunctionPort size / port position
BA 511 301 ExG 1/8"280 l/min-0,9...10 bar14 Nspring returnports at the side