Tecfluid PR Orifice Plate Flowmeter with Bypass

The Tecfluid PR series measures high flow rates using an orifice plate in combination with a bypass flowmeter. The differential pressure generated across the orifice plate is proportional to the main line flow and diverts a small, measurable flow through the bypass meter, providing a local indication of the primary flow. Suitable for liquids, gases, and steam in industrial process lines.

Technical Specifications

  • Water range: 2…20,000 m³/h
  • Air: up to 300,000 Nm³/h
  • Accuracy: ±4% full scale
  • Turndown: 7:1, available in m³/h, kg/h, %, etc.
  • Orifice sizes: DN50…DN1000
  • Pressure tappings: ¾” BSP
  • Orifice plate thickness: 50 mm
  • Materials: painted carbon steel, EN 1.4404 / AISI 316L, PVC, PP

PR and PRC Variants

PR61, PR62, PR31, PR25 are modular: the orifice plate and bypass flowmeter are connected on site via 15/20 mm pipework. PRC61 and PRC31 are compact assemblies integrating orifice, isolation valves, and bypass meter in a single unit.

Temperature and Pressure Ratings

Selection depends on material and submodel. Typical values: PR61/62 Fe or SS -20…+80 °C, PR31 up to +100 °C, plastics up to +60/+80 °C. PR25 SS covers -50…+300 °C, with special options to -180…+400 °C. PR61/62/31 rated up to 15 bar at the bypass; orifice plate pressure class per DN and PN10/PN16.

Outputs and Certifications

Available with reed switches, microswitches, inductive sensors NAMUR EN 60947-5-6, transmitters 4–20 mA, HART, and MODBUS RTU RS485, depending on model. ATEX / IECEx Ex ia or Ex d versions available.

Installation Guidelines

Requires straight pipe runs of 10 × DN upstream and 7 × DN downstream. Pipe must be fully filled; correct flow direction through the orifice is critical to avoid significant indication error. Upstream filtration to 2 mm is recommended.

Description

Description

Medidores de caudal derivado placa orificio para grandes caudales de líquidos, gases y vapor.

Montaje en tuberías horizontales y verticales.

Suministro de placa orificio y caudalímetro en derivación, no de tuberías de conexionado ni válvulas de aislamiento.

Technical specifications

Indication by means of by-pass flowmeter

Measuring ranges

  • 2 m3/h … 20000 m3/h H2O
  • 30 Nm3/h … 300000 Nm3/h air

Accuracy

  • ±4% f.s.

Connections

  • DN50… DN1000
  • Orifice plate mounted between flanges
  • Flowmeter fittings threaded, flanged or solvent weld socket
  • Pressure inlets ¾” BSP

Materials

  • EN 1.4404 (SS 316L), PVC, PP, … others on request

Options

  • 1 or 2 adjustable switches
  • 4-20 mA output, Ex version on request, according to transmitter model
  • HART ™ protocols, Profibus, Fieldbus on request, according to transmitter model