Hafner Electromagnetic Valve Coil Connectors

Hafner connectors are used for the electrical connection of coils in electromagnetic pneumatic valves. Selection is based on coil system, DIN connector form, control voltage, and requirements for LED indication or overvoltage protection via varistor.

Series and Compatibility

  • ST 16: For MA16 coils, Form C per DIN EN 175301-803, 0–250 V, up to 6 A. Available as standard or with LED + varistor for 24 V or 230 V.
  • ST 22: For MA22 coils, Form B per DIN EN 175301-803 / DIN 43650, 0–250 V, up to 10 A. Versions include standard, LED + varistor, and 5000 mm cable.
  • ST 30: For MA30 coils, Form A per DIN EN 175301-803, 0–250 V, up to 16 A, with LED + varistor options.
  • ST 3-10 JPC L300: For MMD valves, with 300 mm cable, 0–24 V, up to 6 A.

Connector Selection

For DC PLC circuits, connectors with LED indication and varistor are preferred for visual status and suppression of inductive voltage spikes during coil deactivation. For auxiliary circuits, standard connectors may be used if external circuit protection is provided.

Application Criteria

Selection must confirm:

  • Coil type: MA16, MA22, MA30, or MMD
  • Connection form: A, B, or C
  • Voltage: 24 V, 230 V, or 0–250 V range
  • Connector current rating
  • Cable direction and length
  • Requirement for LED, varistor, or standard connection

Maintenance

In case of faults, check screw tightness, contacts, cable entry, sealing, oxidation, and polarity (for LED connectors). In ATEX installations, do not replace connectors or coils with non-certified components without verifying valve documentation and certification.

Datasheet and documents

Description

Connector | for MA 16 solenoid system | form C (DIN EN 175301-803)

Type numberVoltageMax. currentLEDVaristorConnectionProtection
ST 16 M0...250 V6 An.a.n.a.Form C (DIN EN 175301-803)Assembled
ST 16 E 1 N0...250 V6 An.a.n.a.Form C (DIN EN 175301-803)Individually packed
ST 162 V 2424 V ± 10 %6 AredavailableForm C (DIN EN 175301-803)LED + Varistor
ST 162 V 230230 V ± 10 %6 AredavailableForm C (DIN EN 175301-803)LED + Varistor

Connector | for MA 22 coils | industrieform B (DIN 436 50)

Type numberVoltageMax. currentLEDVaristorConnectionProtection
ST 22 M0...250 V10 An.a.n.a.Form B (DIN EN 175301-803)Assembled
ST 22 E 1 N0...250 V10 An.a.n.a.Form B (DIN EN 175301-803)Individually packed
ST 222 V 2424 V ± 10 %10 AredavailableForm B (DIN EN 175301-803)LED + Varistor
ST 222 V 230230 V ± 10 %10 AredavailableForm B (DIN EN 175301-803)LED + Varistor
ST 22 L50000...250 V10 An.a.n.a.Form B | Kabel 5000 mmCable

Connector | for MA 30 coils | industrieform A (DIN 436 50-A)

Type numberVoltageMax. currentLEDVaristorConnectionProtection
ST 300...250 V16 An.a.n.a.Form A (DIN EN 175301-803)Assembled
ST 302 V 240...250 V16 AredavailableForm A (DIN EN 175301-803)LED + Varistor
ST 302 V 2300...250 V16 AredavailableForm A (DIN EN 175301-803)LED + Varistor

Stecker | für MMD-Ventile | JPC Standard 300 mm Litze

Type numberVoltageMax. currentLEDVaristorConnectionProtection
ST 3-10 JPC L3000...24 V6 ANicht vorhandenNicht vorhandenLitze | 300 mmLitze