Hafner ATEX Solenoid Valves with NAMUR Interface

Hafner ATEX NAMUR solenoid valves are designed for direct mounting on pneumatic rotary actuators used in process valve automation. The NAMUR interface minimizes external pilot tubing and enables standardized valve–actuator connections in hazardous area applications. The range covers protection types EEx dm IIC T5, EEx d IIC T6, EEx m II T4, EEx ia IIC T6, and EEx e mb IIC T6, in compliance with ATEX directives for explosive atmospheres.

Available Functions

  • 3/2 NC: For single-acting actuators with spring return. Typical codes MNH/MNC 310, G 1/4” or G 1/2”, flow rates 1250 or 3000 l/min.
  • 5/2 monostable: For double-acting actuators, return via pilot air.
  • 5/2 bistable: Two coils, last position maintained until new electrical command.
  • NAMUR-Flex 3/2–5/2: Allows use of a common valve type for different actuator logics.
  • 5/3: Center position centre closed or centre exhausted, for defined behavior on signal loss.

Technical Data

Standard flow rates are 1250 l/min for NAMUR 1/4” and 3000 l/min for NAMUR 1/2”. Operating pressures typically 2…10 bar, 1…10 bar, or 3…10 bar for 5/3 types. Coil consumption is 3 W DC / 5 VA AC. Stainless steel (INOX VES) and low-temperature (TT, -50…+50 °C) versions are available for selected models.

Selection Criteria

Selection must confirm:

  • ATEX zone and coil protection type,
  • single or double acting actuator,
  • fail-open / fail-close position,
  • 3/2, 5/2, or 5/3 logic,
  • NAMUR 1/4” or 1/2” interface,
  • requirement for stainless steel body,
  • correct coil voltage and certified electrical connector.

Maintenance

Check NAMUR O-rings, exhaust port leakage, instrument air cleanliness, Ex wiring condition, and coil certification compatibility. Coil replacement in ATEX installations must use an equivalent certified component.

Datasheet and documents

Description

Ignition protection type

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex dmG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | NC | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 310 701 Ex dG 1/4"1250 l/min2...10 barmonostabil | NC3 W / 5 VANAMUR [G 1/4"]

5/2-way valves

Explosionsgeschützte Magnetventile mit NAMUR-Schnittstelle | monostabil | Luftfederrückstellung | mit Handhilfsbetätigung | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNC 510 701 Ex dG 1/4"1250 l/min2...10 barmonostabil3 W / 5 VANAMUR [G 1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex mG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex mG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex mG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex mG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex mG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex mG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex mG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex iaG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VA
NAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 TT Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof valve with NAMUR interface | monostable | air spring return | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 VES Ex iaG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex iaG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 TT Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 VES Ex iaG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | INOX | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 VES Ex iaG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex iaG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | -50°C...+50°C | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 TT Ex iaG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]

3/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]
MNH 310 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | NC | air spring return | with manual override | ports 1 and 3 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 310 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid | NC3 W / 5 VANAMUR [1/4"]

5/2-way valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 701 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]
MNH 510 121 Ex e mbG 1/2"3000 l/min1...10 barsingle solenoid3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | ports 2 and 4 are swapped | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 510 711 Ex e mbG 1/4"1250 l/min2...10 barsingle solenoid3 W / 5 VANAMUR [1/4"]

Explosion proof solenoid valve with NAMUR interface | bistable | with manual override | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 520 701 Ex e mbG 1/4"1250 l/min2...10 bardouble solenoid3 W / 5 VANAMUR [1/4"]
MNH 520 121 Ex e mbG 1/2"3000 l/min1...10 bardouble solenoid3 W / 5 VANAMUR [1/2"]

NAMUR-Flex | 3/2 - 5/2 valves

Explosion proof solenoid valve with NAMUR interface | monostable | air spring return | with manual override | 3/2 - 5/2 way NAMUR-flex | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 350 701 Ex e mbG 1/4"1250 l/min2...10 barNamur-Flex (3/2 - 5/2-way)3 W / 5 VANAMUR [1/4"]

5/3-way valves

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre closed | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 531 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/4"]
MNH 531 121 Ex e mbG 1/2"3000 l/min1...10 bar5/3-way | centre closed3 W / 5 VANAMUR [1/2"]

Explosion proof solenoid valve with NAMUR interface | spring return to middle position | with manual override | centre exhausted | ATEX

Type numberPort sizeAir flowOperating pressureFunktionPower consumptionInterface
MNH 532 701 Ex e mbG 1/4"1250 l/min3...10 bar5/3-way | centre exhausted3 W / 5 VANAMUR [1/4"]