Impact Disk Flowmeter Tecfluid DP

The Tecfluid DP series is a metallic impact disk flowmeter designed for liquid measurement and, under specific conditions, for gases. Measurement is based on the force exerted by the flow on a disk positioned within the pipe cross-section. Disk displacement is transmitted to the indicator via magnetic coupling, eliminating direct fluid ingress into the indicator housing.

Operating Ranges

  • Water: 0.8–1600 m³/h
  • Air: 45–24000 Nm³/h
  • Accuracy: DP65 ±2.5% full scale, optionally ±1.6% full scale
  • Accuracy: DP500 ±4% full scale
  • Fluid temperature: -20…+150 °C (steel or AISI 316L/PTFE)
  • AISI 316L with bronze bearings: up to +300 °C
  • Pressure ratings: DP65 DN40–DN80 PN40, DN100–DN300 PN16, DP500 DN250–DN500 PN10

Versions and Materials

The DP65 is wafer-mounted between EN 1092-1 flanges, DN40–DN300. The DP500 is supplied flanged for DN250–DN500. Body materials include galvanized/painted steel or EN 1.4404 / AISI 316L. Indicator housing is IP65 aluminum or optional AISI 316L IP67.

Output Devices and Automation

  • AMM: 1 or 2 adjustable microswitches
  • AMD: 1 or 2 NAMUR EN 60947-5-6 inductive sensors
  • TH7 / TH7H: 4–20 mA transmitter, digital output, HART (H version)
  • TH7T / TH7TH: transmitter with totalizer
  • MT03A: converter with optional MODBUS RTU RS485

Installation

Straight pipe runs of 3 × DN upstream and downstream are required for liquids. For gases, the manual recommends 8 × DN. Flanges, gaskets, and internal pipe diameter must not restrict disk movement.

Applications

Suitable for water circuits, heating/cooling, fire protection, chemical and pulp/paper processes, lubricants, cutting oils, and fluids with suspended solids. For extreme temperatures, a thermal spacer is available for -180…+400 °C, depending on DN and electronics.

Description

Description

Medidores de caudal por disco de choque para lÍquidos y gases. Construcción metálica, sencilla y robusta. Particularmente indicados para la medida de fluidos con materias en suspensión y para trabajar en condiciones extremas de presión y temperatura.

Baja pérdida de carga. Requiere instalación de tubería de tramo recto de sólo DNx3 antes y después del caudalímetro.

Technical specifications

Available for all flow directions

  • Housing in aluminium
  • Local indication

Measuring range

  • 0,8m3/h … 1600 m3/h H2O
  • 45 Nm3/h … 24000 Nm3/h air

Accuracy

  • DP65 model ±2,5% f.s. (+-1,6% f.e. on request)
  • DP500 model ±4,0% f.s

Connections

  • DP65 model DN40 … DN300 between flanges
  • DP500 model DN250 … DN500 flanged
  • Standard flange connection according to DIN 2501. Others on request.

Materials

  • Coated steel, EN 1.4404 (SS 316L)

Options

  • 1 or 2 adjustable switches
  • Electronic transmitter wit 4-20 mA, analog output for safe or hazardous area (Ex ia IIC T4 or T6 protection, ATEX certified)
  • HART ™ protocol on request
  • Local volume totalizer. Remote volume totalizer by means of pulse output (not available for Ex transmitters)

Declarations of Conformity

Certifications